Micronutrient testing

Macronutrient and micronutrient levels in plant tissue, growing media or nutrient solution, measured by ICP rather than estimated from a colour chart. Reported against the sufficiency range for the crop stage you tell us.

Price
Quoted
Turnaround
5–7 business days
Family
Analyte panel
Runs on
  • Agilent ICP-OES
  • Agilent 7850 ICP-MS
  • pH meter and conductivity probe

Purchased new through authorised channels, performance-qualified by certified engineers, and the instrument ID prints on every certificate. View the bench.

What the panel measures

TestMethodInstrumentReports as
MacronutrientsMethodICP-OES after microwave digestionInstrumentAgilent ICP-OESReports as% dry weight: N, P, K, Ca, Mg, S
MicronutrientsMethodICP-MS, He collision cellInstrumentAgilent 7850 ICP-MSReports asppm: B, Zn, Fe, Mn, Cu, Mo
Sodium and chlorideMethodICP-OES and titrationInstrumentAgilent ICP-OESReports asppm, salinity indicator
Growing media pH and ECMethodSaturated media extractInstrumentpH meter and conductivity probeReports aspH units and mS/cm
Nutrient solutionMethodDirect ICP after acidificationInstrumentAgilent 7850 ICP-MSReports asppm per element
Sufficiency comparisonMethodAgainst published ranges by crop stageInstrumentDerived from the assayReports asLow, sufficient or high per element

Sample requirements and shipping

ItemRequirement
Plant tissueRequirement20 recently matured leaves, paper bag, not plastic
Growing mediaRequirement200 g, sealed, taken from the root zone
Nutrient solutionRequirement250 mL in a clean bottle, no headspace
ConditionRequirementTell us the crop and growth stage so the sufficiency comparison means something.

Order first, then ship. A prepaid label is emailed when payment lands, and the carrier scan on that label opens your chain of custody. We accept no walk-in drop-off, and we hold no DEA registration, so no Schedule I to V material.

Why the method matters

A tissue test taken from the wrong leaf at the wrong stage produces a confident number about nothing. We ask for recently matured leaves and the growth stage, and we state both on the certificate so the result stays interpretable months later.

Digestion matters as much as detection. We microwave-digest in closed vessels so volatile elements are not lost, which is where open hotplate methods quietly understate boron and sulphur.

What comes back

A public certificate

Every result, the method, the instrument ID, the LOD and LOQ and the signature, verifiable by accession number with no login.

The filmed route

Your package opened on camera, a photograph of each container, and the footage retained for three years. Released to you on request.

A retained sample

Held 90 days, so any result can be rechecked by us or by an accredited laboratory of your choosing.

Questions about micronutrient testing

Do you test the nutrient solution as well as the plant?

Yes, and running both on the same visit is how most growers find the problem: the solution shows what was offered, the tissue shows what was taken up.

How is this different from a heavy metals screen?

Different purpose and different reporting. Micronutrient work reports elements you want present, against sufficiency ranges. A heavy metals screen reports contaminants against safety limits.

Can you sample for us?

Yes within the greater Houston area. Field collection with documented chain of custody is quoted per visit.

Do you report nitrate separately from total nitrogen?

Yes on request. Nitrate by ion chromatography is an add-on and is useful when you suspect luxury uptake rather than a deficiency.

Submit a sample

Order in the builder, pay, and a prepaid label is emailed to you. The certificate publishes to the database the moment it is signed.

Submit a sampleVerify a certificate