Skip to content
5151 Mitchelldale St A10 STE B, Houston, TX 77092. 346 770 3170, 10 AM–4 PM CST.Operated to ISO/IEC 17025 expectations. Client portal
Gold StandardANALYTICSClient portalSubmit samples

Plant growth regulator testing

Plant growth regulators are banned on consumable crops in most states and are not covered by every pesticide panel. They are screened here specifically, by LC-MS/MS, to parts per billion.

Price
Quoted
Turnaround
5–7 business days
Family
Analyte panel
Runs on
  • Agilent 6490 Triple Quadrupole

Purchased new through authorised channels, performance-qualified by certified engineers, and the instrument ID prints on every certificate. View the bench.

What the panel measures

TestMethodInstrumentReports as
PaclobutrazolMethodLC-MS/MS, MRMInstrumentAgilent 6490 Triple QuadrupoleReports asppb, LOQ 5 ppb
DaminozideMethodLC-MS/MS, MRMInstrumentAgilent 6490 Triple QuadrupoleReports asppb, LOQ 5 ppb
Chlormequat chlorideMethodLC-MS/MSInstrumentAgilent 6490 Triple QuadrupoleReports asppb
AncymidolMethodLC-MS/MSInstrumentAgilent 6490 Triple QuadrupoleReports asppb
UniconazoleMethodLC-MS/MSInstrumentAgilent 6490 Triple QuadrupoleReports asppb
Flurprimidol and mepiquatMethodLC-MS/MSInstrumentAgilent 6490 Triple QuadrupoleReports asppb
Limit comparisonMethodAgainst the state limit you nameInstrumentDerived from the assayReports asPass or fail per analyte

Sample requirements and shipping

ItemRequirement
Flower or biomassRequirement5 g sealed
Extract or concentrateRequirement1 g sealed
Growing media or nutrientRequirement200 g or 250 mL, to trace a source
ConditionRequirementRoom temperature. If you are tracing a source, send the input alongside the plant material.

Order first, then ship. A prepaid label is emailed when payment lands, and the carrier scan on that label opens your chain of custody. We accept no walk-in drop-off, and we hold no DEA registration, so no Schedule I to V material.

Why the method matters

Standard multi-residue pesticide panels do not always include growth regulators, because they are not pesticides. A product can pass a pesticide screen and still carry paclobutrazol, which is why this is offered as its own panel.

Regulators persist in growing media and can carry into a following crop. Testing the medium alongside the plant is how growers find out whether the problem is this cycle or the bench it was grown on.

What comes back

A public certificate

Every result, the method, the instrument ID, the LOD and LOQ and the signature, verifiable by accession number with no login.

The filmed route

Your package opened on camera, a photograph of each container, and the footage retained for three years. Released to you on request.

A retained sample

Held 90 days, so any result can be rechecked by us or by an accredited laboratory of your choosing.

Questions about plant growth regulator testing

Is this included in your pesticide screen?

The common regulators are included in our multi-residue panel, but this focused panel goes lower and covers compounds a general screen can miss. If a buyer asks for PGRs by name, order this.

Why would a regulator show up if I did not use one?

Contaminated nutrients, reused media, or drift from a neighbouring operation. Sending the medium and the nutrient alongside the plant usually settles it in one submission.

What is the detection limit?

5 ppb for paclobutrazol and daminozide against certified reference standards. Each LOQ prints beside its result.

Do you test the nutrient solution?

Yes. Send 250 mL in a clean bottle and we report ppb per analyte, which is the fastest way to clear or convict an input.

Submit a sample

Order in the builder, pay, and a prepaid label is emailed to you. The certificate publishes to the database the moment it is signed.

Submit a sampleVerify a certificate