Skip to content
5151 Mitchelldale St A10 STE B, Houston, TX 77092. 346 770 3170, 10 AM–4 PM CST.Operated to ISO/IEC 17025 expectations. Client portal
Gold StandardANALYTICSClient portalSubmit samples

Vitamin E acetate testing

Vitamin E acetate is a diluent that nobody should find in an inhaled product, and its presence is the single most consequential adulteration question in the vape market. We screen for it by LC-MS/MS, alongside the other common cutting agents.

Turnaround
5–7 business days
Family
Analyte panel

Contact us to confirm the sample matrix, analytical scope and price before shipping.

Runs on
  • Agilent 6490 Triple Quadrupole
  • Agilent 8890 GC with 5977 MSD
  • Agilent 1290 Infinity II UHPLC

Purchased new through authorised channels, performance-qualified by certified engineers, and the instrument ID prints on every certificate. View the bench.

What the panel measures

TestMethodInstrumentReports as
Vitamin E acetateMethodLC-MS/MS, MRM against reference standardInstrumentAgilent 6490 Triple QuadrupoleReports asDetected or not detected, ppm, LOQ 5 ppm
Medium chain triglyceridesMethodLC-MS/MS screenInstrumentAgilent 6490 Triple QuadrupoleReports asDetected or not detected, % w/w
Propylene glycolMethodHeadspace GC-MSInstrumentAgilent 8890 GC with 5977 MSDReports as% w/w
Polyethylene glycolMethodLC-MS/MS screenInstrumentAgilent 6490 Triple QuadrupoleReports asDetected or not detected
Squalene and other diluentsMethodLC-MS/MS screenInstrumentAgilent 6490 Triple QuadrupoleReports asDetected or not detected
Cannabinoid potencyMethodHPLC-UV, paired on the same sampleInstrumentAgilent 1290 Infinity II UHPLCReports as% w/w, shows the dilution mass balance

Sample requirements and shipping

ItemRequirement
Vape cartridgeRequirement1 cart, unopened
Distillate or oilRequirement1 g sealed
Disposable deviceRequirement1 device, unopened
ConditionRequirementRoom temperature. Note the fill weight so we can report per cartridge.

Confirm the scope and quote before shipping. Shipping instructions follow the agreed testing order. We accept no walk-in drop-off, and we hold no DEA registration, so no Schedule I to V material.

Why the method matters

Pairing the diluent screen with potency gives a mass balance. When cannabinoids account for far less of the mass than the label implies, something is making up the difference, and that is worth identifying before a product ships.

Detection at 5 ppm is well below any level at which a diluent would be used functionally, so a not-detected result is a meaningful answer rather than an artefact of a blunt method.

What comes back

A public certificate

Every result, the method, the instrument ID, the LOD and LOQ and the signature, verifiable by accession number with no login.

The filmed route

Your package opened on camera, a photograph of each container, and the footage retained for three years. Released to you on request.

A retained sample

Held 90 days, so any result can be rechecked by us or by an accredited laboratory of your choosing.

Questions about vitamin e acetate testing

Is vitamin E acetate still a real risk?

It is far less common than in 2019, but it still appears in unregulated supply. A buyer asking for the screen is asking a reasonable question, and it is cheap to answer.

What does a not-detected result mean?

That the analyte is below 5 ppm, our limit of quantitation, which prints on the certificate. It is not a claim of absolute absence, and no honest laboratory will make one.

Can I run this with potency?

Yes, on the same submitted cartridge, and the combination is more informative than either alone because of the mass balance.

Do you screen other cutting agents?

MCT oil, propylene glycol, polyethylene glycol and squalene are included. If you suspect something else, tell us and we will say whether we hold a standard for it.

Confirm testing scope

Order in the builder, pay, and a prepaid label is emailed to you. The certificate publishes to the database the moment it is signed.

Confirm scope and pricingVerify a certificate