Edibles testing
The number on an edible label is per serving, so that is what we report. Alongside it, the figure that decides whether the label is honest across a batch: how much one gummy differs from the next.
- Price
- Quoted
- Turnaround
- 5–7 business days
- Family
- Product
- Agilent 1290 or 6490
- Agilent 1290 Infinity II UHPLC
- Calibrated aw meter
- Incubated plates
- Agilent 7850 ICP-MS
- Agilent 8890 GC with 5977 MSD
Purchased new through authorised channels, performance-qualified by certified engineers, and the instrument ID prints on every certificate. View the bench.
What the panel measures
| Test | Method | Instrument | Reports as |
|---|---|---|---|
| Potency per serving | MethodHPLC-UV or LC-MS/MS on whole units | InstrumentAgilent 1290 or 6490 | Reports asmg per serving and per package |
| Unit homogeneity | MethodReplicate assay, 10 units from the lot | InstrumentAgilent 1290 Infinity II UHPLC | Reports asRelative standard deviation, % |
| Label claim comparison | MethodAgainst the claim you state | InstrumentDerived from the assay | Reports as% of claim, per serving |
| Water activity | MethodCapacitance hygrometer | InstrumentCalibrated aw meter | Reports asaw to 0.01 |
| Microbial | MethodUSP <61>/<62> | InstrumentIncubated plates | Reports asCFU/g, TAMC, TYMC, pathogens |
| Heavy metals | MethodICP-MS | InstrumentAgilent 7850 ICP-MS | Reports asppb: Pb, As, Cd, Hg |
| Residual solvents | MethodHeadspace GC-MS, where extract is used | InstrumentAgilent 8890 GC with 5977 MSD | Reports asppm against USP <467> |
Sample requirements and shipping
| Item | Requirement |
|---|---|
| Gummies or chocolates | Requirement12 units, unopened, in the retail packaging |
| Beverage | Requirement3 sealed units |
| Baked goods | Requirement3 units, shipped so they arrive intact |
| Condition | RequirementTell us the stated serving size and the claim. Without them we can report mg/g but not percentage of claim. |
Order first, then ship. A prepaid label is emailed when payment lands, and the carrier scan on that label opens your chain of custody. We accept no walk-in drop-off, and we hold no DEA registration, so no Schedule I to V material.
Why the method matters
Homogeneity is where most edible programmes fail, and a single-unit assay hides it. Ten units from the same lot, assayed separately, produce a spread figure that tells a retailer whether the label holds across the batch rather than for one lucky gummy.
Water activity predicts shelf stability better than moisture does, and for a sugar-based product it is the number that says whether mould is possible. It runs on the same submission.
What comes back
A public certificate
Every result, the method, the instrument ID, the LOD and LOQ and the signature, verifiable by accession number with no login.
The filmed route
Your package opened on camera, a photograph of each container, and the footage retained for three years. Released to you on request.
A retained sample
Held 90 days, so any result can be rechecked by us or by an accredited laboratory of your choosing.
Questions about edibles testing
How many units should I send?
Twelve for a homogeneity assessment: ten assayed, two retained. Three units is enough for a straight potency check without the spread.
Do you assay the whole gummy?
Yes. We homogenise whole units rather than sampling a slice, because actives are rarely distributed evenly through a moulded product.
What spread is acceptable?
Most specifications ask for ±10% of claim per unit. We report the actual relative standard deviation and each unit result, and you compare against your own specification.
Can you support an expiry date?
Yes, through a stability study with timed pulls. Water activity at day zero is the cheapest predictor, and the study makes the date defensible.
Submit a sample