Full panel testing
Everything on one sample and one certificate: what the product contains, and every contaminant class a buyer is likely to ask about. Ordered as a panel it costs less than the assays bought separately and arrives as a single document.
- Price
- Quoted
- Family
- Programme
- Agilent 1290 Infinity II UHPLC
- Agilent 8890 GC with 5977 MSD
- Agilent 6490 Triple Quadrupole
- Agilent 7850 ICP-MS
- Plates and thermal cycler
- Moisture balance and aw meter
Purchased new through authorised channels, performance-qualified by certified engineers, and the instrument ID prints on every certificate. View the bench.
What the panel measures
| Test | Method | Instrument | Reports as |
|---|---|---|---|
| Cannabinoid potency | MethodHPLC-UV 228 nm, 16 cannabinoids | InstrumentAgilent 1290 Infinity II UHPLC | Reports as% w/w, totals calculated |
| Terpene profile | MethodHeadspace GC-MS, 42 terpenes | InstrumentAgilent 8890 GC with 5977 MSD | Reports asmg/g each and total |
| Pesticides | MethodLC-MS/MS and GC-MS/MS multi-residue | InstrumentAgilent 6490 Triple Quadrupole | Reports asppb per analyte |
| Mycotoxins | MethodLC-MS/MS, isotope dilution | InstrumentAgilent 6490 Triple Quadrupole | Reports asppb, aflatoxins and OTA |
| Heavy metals | MethodICP-MS, He collision cell | InstrumentAgilent 7850 ICP-MS | Reports asppb: Pb, As, Cd, Hg |
| Residual solvents | MethodHeadspace GC-MS, USP <467> | InstrumentAgilent 8890 GC with 5977 MSD | Reports asppm, 16 analytes |
| Microbial | MethodUSP <61>/<62> and qPCR | InstrumentPlates and thermal cycler | Reports asCFU/g and pathogen detection |
| Moisture and water activity | MethodLoss on drying and capacitance aw | InstrumentMoisture balance and aw meter | Reports as% and aw to 0.01 |
Sample requirements and shipping
| Item | Requirement |
|---|---|
| Flower | Requirement10 g sealed, enough for every assay plus a retain |
| Concentrate | Requirement3 g in the retail container |
| Finished product | Requirement6 retail units, unopened |
| Condition | RequirementOne submission covers the whole panel. The intake builder confirms the quantity once you pick the assays. |
Order first, then ship. A prepaid label is emailed when payment lands, and the carrier scan on that label opens your chain of custody. We accept no walk-in drop-off, and we hold no DEA registration, so no Schedule I to V material.
Why the method matters
Running every assay off one homogenate is more defensible than assembling a certificate from samples taken on different days. The whole panel describes the same material, and the record shows it.
A full panel combines chemistry and microbiological assays. Review the selected scope and sample requirements before ordering.
What comes back
A public certificate
Every result, the method, the instrument ID, the LOD and LOQ and the signature, verifiable by accession number with no login.
The filmed route
Your package opened on camera, a photograph of each container, and the footage retained for three years. Released to you on request.
A retained sample
Kept about 90 days, so a disputed result can be reviewed and, where warranted, rerun or sent to another laboratory.
Questions about full panel testing
Is the panel cheaper than ordering the assays separately?
Yes, because the preparation and accessioning happen once rather than eight times. We quote the bundle against the sum of the individual assays so you can see both figures before you decide.
Can I drop assays I do not need?
Yes, every panel is editable in the builder and the price moves with it. Nothing is bundled that you cannot remove.
Do I get one certificate or several?
One, with every assay on it and the instrument named per result. It carries a single accession number and a single hash.
Submit a sample
Order in the builder, pay, and a prepaid label is emailed to you. The certificate publishes to the database the moment it is signed.