Petroleum hydrocarbon, BTEX and PAH testing in soil, water and oil

TCEQ Method 1005 is the Texas method for total petroleum hydrocarbons: an n-pentane extraction and GC-FID with n-alkane markers at nC6, nC12, nC28 and nC35 so the data user can see the carbon-range distribution. We run 1005 with the chromatogram on the certificate, then BTEX by GC-MS and the 16 priority PAHs where the >nC12 range triggers them.

Turnaround
5–7 business days
Certificate
Public, hashed, video-linked

Contact us to confirm the sample matrix, analytical scope and price before shipping.

Confirm scope and pricingInteractive page and calculators
Hydrocarbons testing at Gold Standard Analytics, Houston

What the panel measures

TestMethodInstrumentReports as
Total petroleum hydrocarbonsMethodTCEQ Method 1005, n-pentane extraction, GC-FID, carbon-range markersInstrumentAgilent GC-FIDReports asmg/kg or mg/L by range; MRL 50 mg/kg soil, 5 mg/L water
TPH fractionationMethodTCEQ Method 1006 aliphatic/aromaticInstrumentAgilent GC-FIDReports asmg/kg by fraction; add-on
BTEX and MTBEMethodEPA 8260 purge-and-trap GC-MSInstrumentAgilent GC-MS with headspaceReports asµg/kg or µg/L
PAH 16MethodEPA 8270 SIM GC-MSInstrumentAgilent GC-MS with headspaceReports asµg/kg or µg/L; quoted add-on
MetalsMethodEPA 200.8 / 6020 ICP-MSInstrumentAgilent 7850 ICP-MSReports asmg/kg or µg/L; add-on

Accepted: Soil, 250 g in glass Groundwater, 2 × 1 L amber Fuels and used oil Sediment Wastewater

Compounds: TPH nC6–nC12, >nC12–nC28, >nC28–nC35 Benzene, toluene, ethylbenzene, xylenes MTBE 16 EPA priority PAHs Naphthalene

Why the method matters

Carbon-range chromatogram on the certificate

Method 1005 exists to show the distribution, not one number. We print the FID trace with the alkane markers so a reviewer can see gasoline from diesel from lube oil at a glance.

PAHs by SIM, as TCEQ recommends

TCEQ guidance recommends 8270 in selected-ion-monitoring mode to minimize false positives at action levels. We run SIM by default.

Authentic Agilent bench, OEM consumables

Every instrument was bought new through Agilent, Charles River and MilliporeSigma authorized channels, installed and performance-qualified by certified engineers, and serviced by Quantum Analytics. Columns, lamps, seals, cartridges, canisters and reference standards are OEM or Thermo Fisher lot-traced; no third-party refills, no re-used cartridges, no expired lysate. The instrument ID, column lot and standard lot are printed on every certificate.

The bench this runs on

Agilent GC-FID
GSA-GC-02

Agilent GC-FID

8890 GC, dual FID, split/splitless inlet

Total petroleum hydrocarbons by carbon range, TCEQ 1005.

Agilent GC-MS with headspace
GSA-GC-01

Agilent GC-MS with headspace

8890 GC, 5977 MSD, 7697A headspace

Volatiles, residual solvents, BTEX and semivolatiles by EI mass spectrometry.

Agilent 7850 ICP-MS
GSA-ICP-01

Agilent 7850 ICP-MS

G8422AA, helium collision cell, SPS 4 autosampler

Elemental impurities and toxic metals to sub-ppb, internal-standardized.

Purchased new through authorized channels, installed and performance-qualified by certified engineers, run on OEM consumables. Instrument IDs are printed on every certificate. See the full bench.

Hydrocarbon testing compared

Gold Standard AnalyticsTypical
TCEQ 1005 with markers on certificateGold Standard AnalyticsYesTypicalNumber only
PAH by 8270 SIMGold Standard AnalyticsDefaultTypicalFull-scan
TurnaroundGold Standard Analytics5–7 days, guaranteedTypical10–15 days typical
Public certificateGold Standard AnalyticsYesTypicalNo

Named, sourced comparisons with individual laboratories are on the compare page.

Questions about hydrocarbons testing

Can I see the video of my sample being opened?

Yes. Every package is opened on camera, each container is photographed, and the footage is linked to your accession. Custody video and photos are kept for three years; the retained sample itself is kept 90 days for guarantee retests.

What happens if my result fails?

It is published like any other result, with the method, instrument and specification shown. You may order a retest of the retained sample; we never re-run to obtain a better number.

Is TCEQ 1005 accepted for PST closure?

Method 1005 is the TCEQ TPH method for the PST program; 418.1 and 8015 data are not accepted after 2001. Confirm program-specific requirements with your TCEQ project manager; we are not NELAP-accredited.

How should I collect water samples?

Two 1 L amber glass bottles, preserved as directed on the label, on ice, received within 48 hours.

When are PAHs required?

TCEQ guidance calls for PAH analysis on the highest >nC12 sample per source area when that range is detected.

Method references: TCEQ Method 1005 Rev 03 · TCEQ RG-411 PST guidance, PAH by 8270 SIM