Skip to content
5151 Mitchelldale St A10 STE B, Houston, TX 77092. 346 770 3170, 10 AM–4 PM CST.Operated to ISO/IEC 17025 expectations. Client portal
Gold StandardANALYTICSClient portalSubmit samples

Cosmetic and skincare active potency, preservative efficacy and microbial testing

The Modernization of Cosmetics Regulation Act requires brands to substantiate safety and keep records. We quantify the actives you claim, run the 28-day USP <51> antimicrobial effectiveness challenge on your finished formula, count microbial limits, and report heavy metals by ICP-MS, so the safety file holds real numbers.

From
$139
Turnaround
5–7 business days; USP <51> 28 days
Certificate
Public, hashed, video-linked
Submit cosmetics samplesInteractive page and calculators
Cosmetics testing at Gold Standard Analytics, Houston

What the panel measures

TestMethodInstrumentReports as
Active potencyMethodHPLC-UV vs certified referenceInstrumentAgilent 1290 Infinity II UHPLCReports as% w/w and % of label
Preservative efficacyMethodUSP <51>, five-organism challenge, 28 daysInstrumentMicrobiology suiteReports asLog reduction at 7, 14, 28 days; pass/fail
Microbial limitsMethodUSP <61>/<62>InstrumentMicrobiology suiteReports asCFU/g; S. aureus, P. aeruginosa, E. coli, C. albicans absent
Heavy metalsMethodICP-MS: Pb, As, Cd, Hg, Ni, Cr, SbInstrumentAgilent 7850 ICP-MSReports asµg/g vs FDA and Health Canada guidance
Preservative assayMethodHPLC-UV parabens, phenoxyethanolInstrumentAgilent 1290 Infinity II UHPLCReports as% w/w
Restricted substancesMethodGC-MS: 1,4-dioxane, formaldehyde donorsInstrumentAgilent GC-MS with headspaceReports asµg/g; add-on

Accepted: Serums Creams and lotions Cleansers Sunscreens Peptide cosmetics Oils

Compounds: Retinol and retinoids Niacinamide Ascorbic acid and derivatives Hyaluronic acid Copper peptides Argireline Salicylic and glycolic acid Zinc oxide, titanium dioxide Parabens, phenoxyethanol

Why the method matters

Full 28-day <51> challenge

Preservative efficacy cannot be shortened. We inoculate five compendial organisms into your actual formula and read at 7, 14 and 28 days. A rapid screen is not a challenge test.

Actives quantified, not assumed

A formula sheet is not a result. We measure retinol, niacinamide, vitamin C and peptide actives against certified standards so a label claim is defensible.

Authentic Agilent bench, OEM consumables

Every instrument was bought new through Agilent, Charles River and MilliporeSigma authorized channels, installed and performance-qualified by certified engineers, and serviced by Quantum Analytics. Columns, lamps, seals, cartridges, canisters and reference standards are OEM or Thermo Fisher lot-traced; no third-party refills, no re-used cartridges, no expired lysate. The instrument ID, column lot and standard lot are printed on every certificate.

The bench this runs on

Agilent 1290 Infinity II UHPLC
GSA-LC-01

Agilent 1290 Infinity II UHPLC

G7120A pump, G7167B multisampler, G7116B thermostat, DAD. Also on the bench: a 1290 Infinity III and a 1260 Infinity II, not pictured

Purity and potency by UV; 1300 bar, sub-2 µm columns, chromatogram printed on the certificate.

Microbiology suite
GSA-MIC-01

Microbiology suite

Incubators 20–25 °C and 30–35 °C, selective media, BSC

USP <61>/<62> counts and specified organisms; USP <51> challenge.

Agilent 7850 ICP-MS
GSA-ICP-01

Agilent 7850 ICP-MS

G8422AA, helium collision cell, SPS 4 autosampler

Elemental impurities and toxic metals to sub-ppb, internal-standardized.

Agilent GC-MS with headspace
GSA-GC-01

Agilent GC-MS with headspace

8890 GC, 5977 MSD, 7697A headspace

Volatiles, residual solvents, BTEX and semivolatiles by EI mass spectrometry.

Purchased new through authorized channels, installed and performance-qualified by certified engineers, run on OEM consumables. Instrument IDs are printed on every certificate. See the full bench.

Cosmetic testing compared

Gold Standard AnalyticsTypical
USP <51> durationGold Standard AnalyticsFull 28 daysTypicalSome offer 14-day screens
Actives by HPLCGold Standard AnalyticsYesTypicalOften not offered
Metals techniqueGold Standard AnalyticsICP-MSTypicalICP-OES or XRF
Public certificateGold Standard AnalyticsYesTypicalNo

Named, sourced comparisons with individual laboratories are on the compare page.

Questions about cosmetics testing

Can I see the video of my sample being opened?

Yes. Every package is opened on camera, each container is photographed, and the footage is linked to your accession. Custody video and photos are kept for three years; the retained sample itself is kept 90 days for guarantee retests.

What happens if my result fails?

It is published like any other result, with the method, instrument and specification shown. You may order a retest of the retained sample; we never re-run to obtain a better number.

What does MoCRA require me to test?

MoCRA requires adequate safety substantiation and records; it does not name specific tests. Preservative efficacy, microbial limits and heavy metals are the tests FDA and retailers most often expect in the file.

How long does USP <51> take?

28 days of incubation plus setup and reporting, about 30 days total. It cannot be rushed.

How much product?

100 g for preservative efficacy on its own; 50 g covers actives and microbial; a sealed retail unit for metals.

Do you test sunscreens?

Zinc oxide and titanium dioxide content by ICP-MS and organic filters by HPLC-UV. We do not run SPF (in vivo) testing.

Method references: USP <51> Antimicrobial Effectiveness Testing · USP <61>/<62> microbial limits

Other services

Peptides testing · SARMs testing · Kratom testing · Hemp testing · Supplements testing · Raw materials testing · Hydrocarbons testing · Pesticides testing · Water and food testing · Compare labs · Laboratory notes

Submit a sample

An invoice is issued at submission and the prepaid label is emailed when payment lands. Certificates publish in 5–7 business days.

Submit samplesVerify a COA