Multi-residue pesticide testing in produce, botanicals, soil and water

Pesticides span polar and non-polar chemistries, so one instrument misses half the list. We extract by QuEChERS and run both LC-MS/MS and GC-MS multi-residue panels, with glyphosate and AMPA as a separate derivatized method because they do not survive a generic screen.

From
$109
Turnaround
5–7 business days
Certificate
Public, hashed, video-linked
Submit pesticides samplesInteractive page and calculators
Pesticides testing at Gold Standard Analytics, Houston

What the panel measures

TestMethodInstrumentReports as
LC-amenable residuesMethodQuEChERS, LC-MS/MS dMRM, 200+ compoundsInstrumentAgilent 6490 Triple Quadrupole LC/MSReports asµg/kg per analyte; LOQ 10 µg/kg typical
GC-amenable residuesMethodQuEChERS, GC-MS SIM/scan, 150+ compoundsInstrumentAgilent GC-MS with headspaceReports asµg/kg per analyte
Glyphosate and AMPAMethodFMOC derivatization, LC-MS/MSInstrumentAgilent 6490 Triple Quadrupole LC/MSReports asµg/kg; add-on $109
Heavy metalsMethodICP-MSInstrumentAgilent 7850 ICP-MSReports asµg/g; add-on

Accepted: Produce, 500 g Dried botanicals, 50 g Soil, 250 g Water, 1 L Finished foods

Compounds: Organophosphates Carbamates Neonicotinoids Pyrethroids Triazoles Strobilurins Organochlorines Glyphosate and AMPA

Why the method matters

Two platforms, not one

A single LC-MS/MS screen misses organochlorines and many pyrethroids; a GC-only screen misses neonicotinoids and carbamates. We run both from one QuEChERS extract.

Isotope-labeled internal standards

Matrix effects in botanicals suppress or enhance signal. Labeled internal standards correct for it so a low result is real, not an artifact.

Authentic Agilent bench, OEM consumables

Every instrument was bought new through Agilent, Charles River and MilliporeSigma authorized channels, installed and performance-qualified by certified engineers, and serviced by Quantum Analytics. Columns, lamps, seals, cartridges, canisters and reference standards are OEM or Thermo Fisher lot-traced; no third-party refills, no re-used cartridges, no expired lysate. The instrument ID, column lot and standard lot are printed on every certificate.

The bench this runs on

Agilent 6490 Triple Quadrupole LC/MS
GSA-LCMS-01

Agilent 6490 Triple Quadrupole LC/MS

G6490A, iFunnel, 1290 Infinity II front end

Identity by accurate mass and MRM transitions; sub-ppt quantitation with isotope dilution.

Agilent GC-MS with headspace
GSA-GC-01

Agilent GC-MS with headspace

8890 GC, 5977 MSD, 7697A headspace

Volatiles, residual solvents, BTEX and semivolatiles by EI mass spectrometry.

Agilent 7850 ICP-MS
GSA-ICP-01

Agilent 7850 ICP-MS

G8422AA, helium collision cell, SPS 4 autosampler

Elemental impurities and toxic metals to sub-ppb, internal-standardized.

Purchased new through authorized channels, installed and performance-qualified by certified engineers, run on OEM consumables. Instrument IDs are printed on every certificate. See the full bench.

Pesticide testing compared

Gold Standard AnalyticsTypical
LC and GC platformsGold Standard AnalyticsBothTypicalOften LC only
GlyphosateGold Standard AnalyticsDedicated methodTypicalFrequently not offered
Internal standardsGold Standard AnalyticsIsotope-labeledTypicalExternal calibration
Public certificateGold Standard AnalyticsYesTypicalNo

Named, sourced comparisons with individual laboratories are on the compare page.

Questions about pesticides testing

Can I see the video of my sample being opened?

Yes. Every package is opened on camera, each container is photographed, and the footage is linked to your accession. Custody video and photos are kept for three years; the retained sample itself is kept 90 days for guarantee retests.

What happens if my result fails?

It is published like any other result, with the method, instrument and specification shown. You may order a retest of the retained sample; we never re-run to obtain a better number.

How many pesticides are on the panel?

Over 350 across the LC-MS/MS and GC-MS lists; the analyte list ships with the certificate.

Why is glyphosate separate?

It is too polar for generic extraction and ionization; it needs derivatization and its own calibration.

What sample size?

500 g produce, 50 g dried material, 250 g soil, 1 L water; glyphosate needs 50 g more.

Method references: QuEChERS and multi-residue LC-MS/MS, GC-MS practice